Analysis Of Radiation Dose in Lung Cancer Using Intensity Modulated Radiotherapy Technique to Minimize Exposure to Organ At Risk
DOI:
https://doi.org/10.25077/jfu.15.5.529-535.2026Keywords:
Conformity Index, Dose Volume Histogram, Homogeneity Index, Lung CancerAbstract
Radiation dose analysis of lung cancer using intensity modulated radiotherapy technique has been conducted to minimize exposure to organs at risk. The study was conducted using 5 images of lung cancer patients processed using Eclipse Treatment Planning System (TPS) software at Andalas University Hospital. This study was conducted to determine the radiation dose distribution in lung cancer patients by analyzing the value of Conformity Index (CI), Homogeinity Index (HI), Organ at Risk (OAR) radiation dose based on the Dose Volume Histogram (DVH) curve and the maximum dose received by Planning Target Volume (PTV) based on the results of therapy planning. The analysis is based on the International Commission on Radiation Units and Measures (ICRU) Report 62 and Report 83 for CI and HI values. Radiation dose in OAR lungs and heart was analyzed based on the Quantitative Analysis of Normal Tissue Effect in the Clinic (QUANTEC) reference. The results of the study for CI values obtained values close to 1 based on ICRU Report 62 and HI values close to 0 based on ICRU Report 83. The radiation dose received by the heart OAR is in accordance with the QUANTEC recommendation of <10% while the radiation dose received by the lung OAR there are 2 patients who exceed the volume limit recommended by QUANTEC which is <30-35%. At the maximum dose there are 2 patients who both exceed the recommended dose of ICRU Report 62 by 107%.
References
Asri, Y., Sutapa, G. N., Sudarsana, I. W. B., & Irhas, R. (2022). Perbandingan Radiasi Kanker Serviks Pada Organ Bladder Dengan Radioterapi LINAC Energi 10 MV Menggunakan Teknik 3DCRT dan IMRT Di RSUP Sanglah Denpasar Comparison of Cervical Cancer Radiation in Bladder Organs with 10 MV LINAC Energy Radiotherapy Using 3D. Buletin Fisika, 19(2), 98–105.
BAPETEN. (2013). Perka BAPETEN Nomor 3 Tahun 2013 tentang Keselamatan Radiasi Dalam Penggunaan Radioterapi. BAPETEN Homepage.
Effina, A., Milvita, D., & Ilyas, M. (2022). Distribusi Dosis Radiasi Foton pada Treatment Planning System Menggunakan Teknik 3DCRTdan IMRT untuk Terapi Kanker Serviks. Jurnal Fisika Unand, 11(1), 126–130. https://doi.org/10.25077/jfu.11.1.126-130.2022
Febrietri, O., Milvita, D., & Diyona, F. (2020). Analisis Dosis Radiasi Paru-Paru Pasien Kanker Payudara dengan Teknik Three Dimensional Conformal Radiation Therapy (3D-CRT) Berdasarkan Grafik Dose Volume Histogram (DVH). Jurnal Fisika Unand, 9(1), 110–117. https://doi.org/10.25077/jfu.9.1.110-117.2020
Husni, M., Shafii, M. A., Adrial, R., & Ilyas, M. (2021). Analisis Perbandingan Nilai Conformity Index dan Homogeneity Index pada Teknik 3D-CRT dan IMRT pada Kasus Kanker Payudara Berdasarkan Hasil TPS di RS UNAND. Jurnal Fisika Unand, 10(4), 511–517. https://doi.org/10.25077/jfu.10.4.511-517.2021
Komite Penanggulangan Kanker Nasional. (2015). Panduan Penatalaksanaan Kanker Paru. Kementerian Kesehatan Republik Indonesia, 1–47. https://kanker.kemkes.go.id/guidelines/PPKProstat.pdf
Susworo, R., & Kodrat, H. (2017). Dasar dasar Radioterapi Tata Laksana Radioterapi Penyakit Kanker (Edisi 2). UI Press.
Winarno, W. (2021). Radioterapi Kanker Cervix Dengan Linear Accelerator (LINAC). Jurnal Biosains Pascasarjana, 23(2), 75. https://doi.org/10.20473/jbp.v23i2.2021.75-86
World Health Organization. (2023). Lung Cancer. WHO Homepage. https://www.who.int/news-room/fact-sheets/detail/lung-cancer
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Aulia Miftahul Jannah, Rico Adrial, Fiqi Diyona, Muhammad Ilyas

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.