Analisis Korelasi Usia, Massa Tubuh, mAs, dan Dosis Efektif Terhadap CTDIvol dan DLP pada Pemeriksaan CT-Scan Pasien Dewasa

Authors

  • Wafi Muthia Dewanti Andalas University
  • Dian Milvita Departemen Fisika, Universitas Andalas
  • Ramacos Fardela Departemen Fisika, Universitas Andalas
  • Ida Bagus Gede Putra Pratama Badan Pengawas Tenaga Nuklir (BAPETEN)
  • Sri Herlinda RSUP Dr. M. Djamil Padang

DOI:

https://doi.org/10.25077/jfu.13.4.579-586.2024

Keywords:

Computed Tomography Scanner, Dose Length Product, Correlation , Computed Tomography Dose Index, Volume

Abstract

A research study has been conducted on the correlation analysis of age, body mass, mAs, and effective dose with Computed Tomography Dose Index Volume (CTDIvol) and Dose Length Product (DLP) in CT-Scan examinations at the Radiology Department of Dr. M. Djamil Padang General Hospital. The research utilized data from adult patients aged 15 years and above with a standard body mass (60 ± 10) kg in non-contrast CT scans of the head, chest, and abdomen, with a total of 586 patients collected over a period of 3 months. The analysis was conducted using Pearson correlation test. The research results indicate that the effective dose has a very high correlation with DLP, with a coefficient of 1 and mAs has a very high correlation with CTDIvol and DLP, with a coefficient of 0,9. Body mass has a relatively high correlation with CTDIvol and DLP, ranging from 0,4 to 0,7 except in head examinations. Age has a moderately significant correlation with CTDIvol and DLP, ranging from 0,1 to 0,5.

Author Biography

Wafi Muthia Dewanti, Andalas University

Departemen Fisika dan mahasiswa

References

Amalia, T., Zulkarnaien, B., Anam, C., Nurcahyo, K., Tussyadiah, H., & Pradana, D. E. (2022). The Establishment of Institutional Diagnostic Reference Levels (DRLs) in the Cipto Mangunkusumo Hospital. Atom Indonesia, 48(2), 159-167. https://doi.org/10.17146/aij.2022.1131

Annisah, R. (2023). Penentuan Nilai Diagnostic Reference Level CT-Scan di Rumah Sakit Universitas Tanjungpura Pontianak. Prisma Fisika, 10(3), 387-391. https://doi.org/10.26418/pf.v10i3.59891

BAPETEN. (2020). Peraturan Kepala Badan Pengawas Tenaga Nuklir Nomor 4 Tahun 2020 Tentang Keselamatan Radiasi dalam Penggunaan Pesawat Sinar-X Radiologi Diagnostik dan Intervensional.

BAPETEN. (2021). Pedoman Teknis Penerapan Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level).

Bushberg, J.T., Seibert, J.A., Leidholot, E.M., dan Boone, J. M. (2021). The Essential Physics of Medical Imaging. In Radiology. https://doi.org/10.1148/radiology.191.3.786

Bushong, S. C. (2013). Radiologic Science for Technologists: Physics, Biology, and Protection.

Hiswara, E. (2023). Buku Pintar Proteksi dan Keselamatan Radiasi. In BRIN. Jarkarta.

Ibrahim, A. A., Abdullah, B., & Halide, H. (2018). Estimasi Dosis Efektif Pasien Bagian Abdomen dari Hasil Pemeriksaan CT-Scan Merek Siemens SOMATOM. Positron, 8(2), 39-42. https://doi.org/10.26418/positron.v8i2.25213

Jannah, R., Munir, R., & Putri, E. R. (2023). Determination of the Diagnostic Reference Level ( DRL ) in Samarinda Hospitals. 49(3), 145–150. https://aij.batan.go.id/index.php/aij/article/view/1285/ 1092

Luo, L., & Liu, M. (2016). Adipose tissue in control of metabolism. Journal of Endocrinology, 231(3), 77–99. https://doi.org/10.1530/JOE-16-0211

Martinez-Maza, C., Rosas, A., & Nieto-Díaz, M. (2013). Postnatal changes in the growth dynamics of the human face revealed from bone modelling patterns. Journal of Anatomy, 223(3), 228-241. https://doi.org/10.1111/joa.12075

Moifo, B., Tapouh, J. R. M., Guena, M. N., Ndah, T. N., Samba, R. N., & Simo, A. (2017). Diagnostic Reference Levels of Adults CT-Scan Imaging in Cameroon: A Pilot Study of Four Commonest CT-Protocols in Five Radiology Departments. Open Journal of Medical Imaging, 07(01), 1-8. https://doi.org/10.4236/ojmi.2017.71001

Nuraeni, S. P., Mufida, W., & Aeni, A. R. (2021). Pengaruh Perubahan Faktor Ekposi Terhadap Dosis Radiasi pada Pemeriksaan Multislice Computed Tomography. http://digilib.unisayogya.ac.id/id/ eprint/6038

O’Neill, S., Kavanagh, R. G., Carey, B. W., Moore, N., Maher, M., & O'Connor, O. J. (2018). Using body mass index to estimate individualised patient radiation dose in abdominal computed tomography. European Radiology Experimental, 2(1), 0–7. https://doi.org/10.1186/s41747-018-0070-5

Peraturan Pemerintah. (2023). Peraturan Pemerintah Republik Indonesia Nomor 45 Tahun 2023 tentang Keselamatan Radiasi Pengion dan Keamanan Zat Radioaktif. Peraturan Pemerintah Republik Indonesia Nomor 45 Tahun 2023 Tentang Keselamatan Radiasi Pengion Dan Keamanan Zat Radioaktif.

Rosalina, L., Oktarina, R., Rahmiati, & Saputra, I. (2023). Buku Ajar Statistika. In MRI Publisher. Padang.

Siregar, E. S. ., Sutapa, G. N., & Sudarsana, I. W. B. (2020). Analysis of Radiation Dose of Patients on CT Scan Examination using Si-INTAN Application. Buletin Fisika, 21(2), 53–59. https://doi.org/10.24843/bf.2020.v21.i02.p03

Downloads

Published

2024-07-01

How to Cite

Dewanti, W. M., Milvita, D., Fardela, R., Pratama, I. B. G. P., & Herlinda, S. (2024). Analisis Korelasi Usia, Massa Tubuh, mAs, dan Dosis Efektif Terhadap CTDIvol dan DLP pada Pemeriksaan CT-Scan Pasien Dewasa. Jurnal Fisika Unand, 13(4), 579–586. https://doi.org/10.25077/jfu.13.4.579-586.2024

Issue

Section

Articles