Abstract

Research has been conducted on the correlation analysis of age, body mass, and exposure factors to Entrance Surface Air Kerma (ESAK) in the Radiology Installation of Andalas University Hospital. The study was conducted by collecting data on adult thorax examination patients over 15 years of age and body mass (60 ± 10) kg in Posterior-Anterior (PA) and Anterior-Posterior (AP) projections for ± 5 months. Patient data used in PA projections are 107 patient data with the Automatic Exposure Control (AEC) method, 9 patient data with manual methods and 10 AP projection patient data with manual methods. Analysis was conducted using the Pearson correlation test. The results showed that body mass and exposure factors have a very strong relationship with ESAK as indicated by r = 0.805 to 0.990. As body mass and exposure factor increase, the average ESAK received by patients will increase, while age has a weak relationship with ESAK as shown by r = -0,246 to 0,227.

References

Alghoul A, Y. (2021). Entrance-Surface-Dose Evaluation of Patients Examined by Diagnostic X-rays at Alhilal Alahmar Medical Center. Clinical Radiology & Imaging Journal, 5(2). https://doi.org/10.23880/crij-16000188

Aliasgharzadeh, A., Mihandoost, E., Masoumbeigi, M., Salimian, M., & Mohseni, M. (2015). Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran. Global journal of health science, 7(5), 202-207. https://doi.org/10.5539/gjhs.v7n5p202

Alomairy, N., Hadi, D., Al-Zaid, A., Fasikh, R., Arif, R., Al-Hazmi, R., Kharizy, A., Alyami, A., Hummdy, A., & Shubayr, N. (2023). Evaluation of the Entrance Surface Doses (ESD) for common diagnostic X-ray examinations. Journal of Radiation Research and Applied Sciences, 16(4), 100754. https://doi.org/10.1016/j.jrras.2023.100754

BAPETEN. (2021). Pedoman Teknis Penerapan Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level). 8, 1-4.

Bushong, S. C. (2013). Radiologic Science for Technologists: Physisc, Biology and Protection (Tenth Edit). Elsevier Mosby.

Hiswara, E. (2023). Buku Pintar Proteksi Radiasi dan Keselamatan Radiasi di Rumah Sakit. BRIN.

IAEA. (2007). Dosimetry in Diagnostic Radiology: An International Code of Practice.

Irsal, M., Hidayanto, E., & Arifin, Z. (2014). Analisa Pengaruh Faktor Eksposi Terhadap Entrance Surface Air Kerma (Esak). Youngster Physics Journal, 3(4), 271-278.

Latifah, R., Rosyid, M., Yuana, F., & Hidayat, A. (2020). Estimation of Entrance Surface Dose (Esd) As a Dose Profile for Patients Undergoing Radiography Examination Based on Tube Output Measurement. Journal of Vocational Health Studies, 4(2), 72. https://doi.org/10.20473/jvhs.v4.i2.2020.72-77

Mraity, H. A. A., & Aseebee, M. K. Al. (2021). Evaluation of Entrance Surface Air Kerma in Patients during PA Chest Radiography Using CALDose Program in Al Najaf Governorate Hospitals. Journal of Physics: Conference Series, 1963(1). https://doi.org/10.1088/1742-6596/1963/1/012035

Rosalina, L., Oktarina, R., Rahmiati, & Saputra, I. (2023). Buku Ajar Statistik. MRI Publisher.

Rubai, S. S., Rahman, M. S., Purohit, S., Patwary, M. K. A., Meaze, A. M. H., & AA, M. (2018). Measurements of Entrance Surface Dose and Effective Dose of Patients in Diagnostic Radiography. Biomedical Journal of Scientific & Technical Research, 12(1), 8924-8928. https://doi.org/10.26717/bjstr.2018.12.002186

Sugiarti, S., Merrytiana Fadila, & Surip. (2020). 1543-Article Text-6260-1-10-20200829. Optimasi Faktor Eksposi Pada Pemeriksaan Radiografi Thorax Menggunakan Computed Radiography, 1-5.

Syahmitalia, V., Arifin, Z., & Rusmanto, R. (2021). Analisis Nilai Diagnostic Reference Level (DRL) Dewasa Pemeriksaan Lumbal Spine Anterior-Posterior (AP) dan Lateral (LAT) Modalitas Radiografi Umum di Indonesia Berdasarkan Database Dosis Pasien Si-INTAN. Jurnal Pengawasan Tenaga Nuklir, 1(1), 47–51. https://doi.org/10.53862/jupeten.v1i1.010

Wulandari, P. I., Jeniyanthi, N. P. R., Prasetya, I. M. L., Susanta, I. P. A., Juliantara, I. P. E., & Diartama, A. . A. (2023). EVALUASI DOSIS RADIASI PADA PEMERIKSAAN RADIOGRAFI THORAX. 7, 16325-16330.

Downloads

Published

2024-09-02

How to Cite

Sari, S. I., Milvita, D., Fardela, R., Pratama, I. B. G. P., & S, A. O. (2024). Analisis Korelasi Umur, Massa Tubuh dan Faktor Eksposi Terhadap Entrance Surface Air Kerma pada Pemeriksaan Thorax di Rumah Sakit Universitas Andalas. Jurnal Fisika Unand, 13(5), 602–609. https://doi.org/10.25077/jfu.13.5.602-609.2024

Issue

Section

Articles