Pengaruh Tegangan terhadap Nilai CTDIvol, Dose Length Product dan Dosis Efektif pada Pemeriksaan Computed Tomography (CT) Abdomen: Studi di Rumah Sakit Umum Pusat Dr. M. Djamil
Abstract
Keywords
Full Text:
PDFReferences
AAPM. (2008). The Measurement, Reporting, and Management of Radiation Dose in CT. AAPM report no. 96.
Anam, C., Haryanto, F., Widita, R., Arif, I., Dougherty, G., dan McLean, D. (2018). Volume computed tomography dose index (CTDIvol) and size-specific dose estimate (SSDE) for tube current modulation (TCM) in CT scanning. International Journal of Radiation Research, 16(3).
Blanke, P., Bulla, S., Baumann, T., Siepe, M., Winterer, J. T., Euringer, W., Schäfer, A. O., Kotter, E., Langer, M., dan Pache, G. (2010). Thoracic aorta: Prospective electrocardiographically triggered CT angiography with dual-source CT - Feasibility, image quality, and dose reduction. Radiology, 255(1), 207–217.
Curry, T. S., Dowdey, J. E., dan Murray, R. C. J. (1990). Christensen’s physics of diagnostic radiology 4th edition. Lea and Febiger.
Fitriana, L., dan Utami, H. S. (2021). Perbedaan Nilai Image Noise Dan Dosis Radiasi Dengan Menggunakan Automatic Exposure Control (Aec) Pada Pemeriksaan Ct Scan. Jurnal Kesehatan, 12(2), 131–136.
Gharbi, S., Labidi, S., Mars, M., Chelli, M., Meftah, S., dan Ladeb, M. F. (2018). Assessment of organ dose and image quality in head and chest CT examinations: A phantom study. Journal of Radiological Protection, 38(2), 807–818.
Hidayanto, E., dan Arifin, Z. (2014). Pengaruh Variasi Faktor Eksposi (Tegangan Tabung dan Arus Waktu) serta Pitch terhadap Computed Tomography Dose Index (CTDI) Di Udara Menggunakan CT Dose Profiler. Youngster Physics Journal, 3(4), 364–372.
Ibrahim, A. A., Abdullah, B., dan Halide, H. (2018). Estimasi Dosis Efektif Pasien Bagian Abdomen dari Hasil Pemeriksaan CT-Scan Merek Siemens SOMATOM. Positron, 8(2), 39.
Irsal, M., Nurbaiti, N., Mukhtar, A. N., Gunawati, S., dan Hidayat, W. (2021). Pengaruh Tegangan Tabung terhadap Kualitas Citra pada Pemeriksaan Computed Tomography Kepala menggunakan Iterative Reconstruction. Jurnal Teori dan Aplikasi Fisika, 9(1), 103–110.
Irsal, M., dan Winarno, G. (2020). Pengaruh Parameter Milliampere-Second (mAs) terhadap Kualitas Citra dan Dosis Radiasi Pada Pemeriksaan CT scan Kepala Pediatrik. Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat, 17(1), 1.
Nurhayati, A. Y., Nariswari, N. N., Rahayuningsih, B., dan Hariadi, Y. C. (2019). Analisis Variasi Faktor Eksposi dan Ketebalan Irisan Terhadap CTDI dan Kualitas Citra Pada Computed Tomography Scan (Analysis of Variation of Exposure Factor and Slice Thickness On CTDI and Image Quality at Computed Tomography Scan). Berkala Saintek, 7(1), 7–12.
Satwika, L. G. P., Ratini, N. N., dan Iffah, M. (2021). Pengaruh Variasi Tegangan Tabung Sinar-X terhadap Signal to Noise Ratio (SNR) dengan Penerapan Anode Heel Effect menggunakan Stepwedge Effect of X-ray Tube Voltage Variation on Signal to Noise Ratio (SNR) by Application of Anode Heel Effect using Step. Buletin Fisika, 22, 20–28.
Wahyuni, S., dan Amalia, L. (2022). Perkembangan dan Prinsip Kerja Computed Tomography (CT Scan). GALENICAL : Jurnal Kedokteran dan Kesehatan Mahasiswa Malikussaleh, 1(2), 88.
DOI: https://doi.org/10.25077/jfu.12.4.591-597.2023
Refbacks
- There are currently no refbacks.
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Published by:
Departemen Fisika, FMIPA Universitas Andalas
Kampus Unand Limau Manis Padang Sumatera Barat 25163
Telepon 0751-73307
Email:jfu@sci.unand.ac.id