STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR (STATIK) MENGGUNAKAN SUMBER RADIASI MEDIUM ENERGY RADIUM-226 (RA226)

Resky Maulanda Septiani, Dian Milvita, Fadil Nazir

Abstract


ABSTRAK

Penelitian tentang uji perangkat kamera gamma telah dilakukan di bidang Teknik Nuklir Kedokteran (TNK) Pusat Teknologi Keselamatan dan Metrologi Radiasi (PTKMR) Badan Tenaga Nuklir Nasional (BATAN) Jakarta Selatan. Penelitian ini bertujuan untuk menguji dan menganalisis perangkat kamera gamma dual head model pencitraan planar (statik) menggunakan sumber radiasi medium Energy Ra226. Data penelitian diperoleh dari hasil pencacahan Ra226 dengan aktivitas 0,08 mCi selama 5 menit pada jarak 5 cm, 10 cm, dan 15 cm. Penelitian ini menggunakan kamera gamma Dual Head Mediso S Series As-105061-S, kolimator MEGP, phantom linier dan phantom BAR. Data diolah menggunakan program Statistica 6.0. Hasil penelitian menunjukkan laju cacahan tanpa kolimator MEGP lebih besar dibandingkan menggunakan kolimator MEGP dan laju cacahan menggunakan phantom BAR lebih besar dibandingkan menggunakan phantom linier. Studi awal uji kamera gamma dual head menggunakan sumber radiasi medium energy Ra226, menunjukkan bahwa kamera gamma memberikan tanggapan yang baik dalam mencacah.

Kata kunci: kamera gamma, Ra226, kolimator MEGP, phantom linier, phantom BAR, planar (statik).

ABSTRACT

Preliminary test of dual head gamma camera has performed at TNK PTKMR-BATAN, South Jakarta. The purpose of this study is examine and analyze the dual head gamma camera planar (static) imaging models using a medium energy radiation source Ra226.  The data were obtained from the enumeration of Ra226 with activity 0.08 mCi for 5 minutes at a distance of 5 cm, 10 cm, and 15 cm. This study uses a Dual Head Gamma Camera Mediso S Series As-105061-S, collimator MEGP, linear phantom and BAR phantom. The data were processed using Statistica 6.0 program. Results showed the total count without collimator MEGP greater than using the collimator MEGP and the total count using a linear phantom greater than using BAR phantom. Preliminary test of dual head gamma camera using a medium energy radiation source of Ra226, showed that the gamma camera is able to provide good response in enumerating.

Keywords: gamma camera, Ra226, collimator MEGP, linear phantom,  BAR phantom, planar (static).


Full Text:

PDF


DOI: https://doi.org/10.25077/jfu.3.2.109-114.2014

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License

Published by:

Departemen Fisika, FMIPA Universitas Andalas

Kampus Unand Limau Manis Padang Sumatera Barat 25163

Telepon 0751-73307

Email:jfu@sci.unand.ac.id